This paper presents an experimental study on diagnosis of eccentricity fault in permanent magnet
synchronous motor (PMSM). The study carried out by analyzing the harmonics obtained using Power
Spectral Density (PSD) of stator current and voltage at no load condition. Motor stator current and
voltage are uploaded to pc with software of used inverter and their harmonics obtained by using
LabVIEW Signal Express Toolbox program for healthy and faulty condition. In addition, performance
of the motor over the period of starting up to the steady state is investigated. The experimental results
are illustrated in graph diagrams and results showed that the presented method is very effective and
easy to use for prognosis of static eccentricity fault.
 

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Makaleler
Yazarlar

Mehmet Akar

İlyas Çankaya

Yayımlanma Tarihi 25 Ekim 2010
Yayımlandığı Sayı Yıl 2009 Cilt: 9 Sayı: 2

Kaynak Göster

APA Akar, M., & Çankaya, İ. (2010). DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE. IU-Journal of Electrical & Electronics Engineering, 9(2), 951-958.
AMA Akar M, Çankaya İ. DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE. IU-Journal of Electrical & Electronics Engineering. Ekim 2010;9(2):951-958.
Chicago Akar, Mehmet, ve İlyas Çankaya. “DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE”. IU-Journal of Electrical & Electronics Engineering 9, sy. 2 (Ekim 2010): 951-58.
EndNote Akar M, Çankaya İ (01 Ekim 2010) DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE. IU-Journal of Electrical & Electronics Engineering 9 2 951–958.
IEEE M. Akar ve İ. Çankaya, “DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE”, IU-Journal of Electrical & Electronics Engineering, c. 9, sy. 2, ss. 951–958, 2010.
ISNAD Akar, Mehmet - Çankaya, İlyas. “DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE”. IU-Journal of Electrical & Electronics Engineering 9/2 (Ekim 2010), 951-958.
JAMA Akar M, Çankaya İ. DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE. IU-Journal of Electrical & Electronics Engineering. 2010;9:951–958.
MLA Akar, Mehmet ve İlyas Çankaya. “DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE”. IU-Journal of Electrical & Electronics Engineering, c. 9, sy. 2, 2010, ss. 951-8.
Vancouver Akar M, Çankaya İ. DIAGNOSIS OF STATIC ECCENTRICITY FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR BY ON-LINE MONITORING OF MOTOR CURRENT AND VOLTAGE. IU-Journal of Electrical & Electronics Engineering. 2010;9(2):951-8.