In this study, temperature of an
uninsulated environment was controlled by PID for on-off and various parameter
values using Arduino micro controller. A medium with high heat transmission
and with no insulation materials on the junctions and the surface to prevent
heat transfer into the external environment, is heated by an AC
voltage-operated resistor. Temperature of the heated environment is taken with
LM35 temperature sensor and converted to 0-10V industrial standards. Temperature
information converted to voltage value was applied as an analogue input to the
Arduino Due micro controller and resistance voltage was set via semiconductor
switching path as a result of PID operation. Despite deteriorating experimental
results such as heat loss, it is seen that the reference temperature is
captured by the PID.
Birincil Dil | İngilizce |
---|---|
Konular | Elektrik Mühendisliği |
Bölüm | Araştırma Makalesi |
Yazarlar | |
Yayımlanma Tarihi | 30 Aralık 2017 |
Yayımlandığı Sayı | Yıl 2017 Cilt: 7 Sayı: 2 |
All articles published by EJT are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.